Analysis of Types and Selection of Control Valves in the Power Industry

  • 5781 Views
  • 2017-03-07
Simply put, the power flow diagram is actually a cycle process of water and steam, and selecting control valves in this process is both simple and complex. The simple thing is that the process medium is simple, with only two types: water and steam. The complex thing is that the temperature and pressure fluctuations of water and steam are large, causing a series of problems such as flash evaporation, cavitation, erosion, noise, and corrosion. But the first thing to consider is the safety and reliability of the control valve.

We will follow the system process to provide instructions for selecting control valves.

1. Main and auxiliary boiler feed water valves and composite feed water regulating valves:

Control requirements: Control the boiler inlet water, maintain the boiler liquid level and steam flow.

Working condition requirements: When the boiler is started, the valve pressure difference can reach 100-300 kilograms, and the flow rate is small. During normal operation, the pressure difference is small, and the flow rate is large. The adjustable ratio of flow rate is 75:1 to 100:1.

Valve requirements: The valve body material is WCB/WC9. For start-up valves in dual valve systems, resistance to cavitation is required, with a V-class closure rating. For composite feed water valves, characteristic valve trims are required to meet the needs of boiler start-up and normal operation. Generally, the valve is selected as fault closed. (It should be noted that in order to eliminate dissolved oxygen in the water supply, hydrazine is added for treatment, which can cause adverse reactions to SATELLITE 6 alloy or other similar alloys. Therefore, 316STELLITE surfacing welding method is not used to treat the valve internals, and 416 stainless steel material can be directly used.).

2. Boiler feed pump minimum flow circulation valve:

Control requirements: Ensure the safe start and operation of the boiler feedwater pump, and eliminate pump damage caused by low flow rate, increased temperature rise, and strong water cavitation. (Old power plants used switch type minimum flow control valves, as well as mechanical pump automatic circulation valves.).

Working condition: The pressure drop reaches 160-350 kilograms, and it is the valve that bears the largest pressure difference in the power plant system. The flow rate is generally 30% of the normal flow rate.

Valve requirements: anti cavitation, anti clogging structure, V-class sealing grade, continuous operation of the valve during pump start and stop operation, and closing of the valve after normal pump start. The valve is usually open due to malfunction.

3. High/low heater feed water heater drainage, condensate heater drainage:

Control requirements: Control the position of condensate water in the heater, and timely discharge the condensate water, i.e. discharge at high water level and drain at normal water level.

Working condition: the medium is saturated water, the pressure difference of control valves between heaters is generally 6-30kg, and the last stage drain valve is directly connected to the condenser or deaerator.

Valve requirements: Anti flash erosion, Class V or VI sealing rating, and the valve is usually open due to malfunction.

4. Deaerator water level control valve (DALC):

Control requirements: Provide flow to maintain the normal water level of the deaerator, and increase the water temperature by adding steam to eliminate dissolved gases in the water.

Working condition: During the startup phase, the flow rate is small and the pressure difference is large. Under normal circumstances, the flow rate is large and the pressure difference is small, and the working condition is similar to that of a water supply valve.

Valve requirements: Effective resistance to cavitation at low flow rates.

5. Desuperheating valve (desuperheater):

Control requirements: Inject high-pressure water into the steam to ensure that the steam temperature meets the control requirements.

Working condition: The medium is water, with a large pressure difference. Valve requirements: diverse types: nozzle type, auxiliary atomization type, self contained type, and wafer type.

6. Temperature and pressure reducing valves (high and low pressure bypass valves):

Control requirements: Adjust the high-temperature and high-pressure steam to a certain temperature and pressure of steam; Provide a bypass channel for the steam turbine, and the boiler can operate independently of the steam turbine.
Working condition: High temperature and high pressure steam temperature and pressure reduction.

Valve requirements: thermal shock resistance, noise reduction, rapid response.
主站蜘蛛池模板: 久久久久国产精品免费免费搜索 | 色噜噜狠狠狠狠色综合久不 | 久久久99国产精品免费 | 国产中文字幕视频在线 | 98精品国产自产在线观看 | 国产精品 日韩 | 激情久久久久久久久久久久久久久久 | 久久久久亚洲精品国产 | 精品视频久久 | 99草视频 | 8x成人在线 | 黄色三级网站 | 精品国产亚洲在线 | 91精品啪在线观看国产81旧版 | 久久免费av电影 | 高潮久久久 | 一级片视频在线 | 久久久久久久久久久免费视频 | 亚洲国产欧美在线人成大黄瓜 | 成人免费毛片aaaaaa片 | 91成熟丰满女人少妇 | 日本久久久影视 | 亚洲精品免费在线视频 | 玖玖爱在线观看 | 探花视频网站 | 久久久久久久久久久免费视频 | 久久99在线视频 | 亚洲精品在线一区二区三区 | 国产一级在线播放 | 在线观看免费福利 | 碰天天操天天 | 亚洲国内精品 | 韩国精品一区二区三区六区色诱 | 美女黄视频免费 | 国产精品99久久久久久久久 | 欧美 日韩 久久 | 久草电影免费在线观看 | 中文免费在线观看 | 国产精品日韩欧美 | 久久免费看毛片 | 又爽又黄在线观看 | 69久久久 | 色视频网站免费观看 | 永久免费在线 | 日韩一区二区三区在线观看 | 久99久精品视频免费观看 | 久久久精品国产一区二区三区 | 午夜精品av | 国产字幕av| 色资源网在线观看 | 在线色视频小说 | 亚洲91网站 | 国产午夜精品一区二区三区嫩草 | 激情婷婷六月 | 亚洲丁香日韩 | 日韩av影视在线 | 日韩精品在线一区 | 91视频高清完整版 | 又黄又刺激的视频 | 日韩3区 | 久久国产精品一区二区三区四区 | 日韩精品视频一二三 | 久久欧洲视频 | 日日干日日| 国产人成免费视频 | 亚洲精品国产成人av在线 | 久久精品亚洲 | 亚洲视频播放 | 五月婷婷精品 | 涩涩网站在线播放 | 操操碰 | 欧美色图p | av在线进入 | 四虎5151久久欧美毛片 | 丁香导航| 99精品小视频 | 久久精国产 | 最近日本中文字幕 | 日本天天操 | 在线免费观看黄色大片 | 中国精品一区二区 | 欧美成人h版在线观看 | 色插综合| 亚洲精品美女久久久久网站 | 99久久婷婷国产综合精品 | 久久综合九色综合久久久精品综合 | 91成人免费在线视频 | 国产精品久久网站 | 香蕉视频在线免费 | 成人影视免费看 | 成 人 黄 色 视频 免费观看 | 97精品一区二区三区 | 国产一区二区久久精品 | 在线天堂v| 欧美精品久久 | 一级成人免费视频 | 日日操天天射 | 亚洲国产三级在线 | 一区二区视频在线看 |